XN-1500
Count. Smear. Stain. All-in-one haematology
- Fully integrated slide maker & stainer with small footprint
- Flexible throughput of smear preparation depending on the workload
- Short turnaround times
- Less biohazard procedures
- Optional integration of digital imaging module
For the first time, we have combined our market-leading XN-Series analyser with a brand-new slide maker/stainer in an all-in-one workstation. Should an analysis result lead to a smear, it is performed without manual intervention. The result? Consistent smears with a beautiful cell monolayer that make further microscopic diagnostics as easy and powerful as possible. Add a DI-60, our digital imaging analyser, and microscopic analysis can be performed automatically, too.
Reflex testing occurs within the same loop, and so does the smear preparation when it is needed. Like extended measurements, smears are only initiated if they offer additional diagnostic value. The analysis profile is extended automatically to include smear-making and staining, but you may also order this up front, for instance with known special samples.
Measurement principles | WBC DIFF/RET/PLT-F/WPC: Fluorescence Flow Cytometry RBC/PLT: Hydrodynamically focussed impedance HGB: Cyanide-free SLS haemoglobin |
Aspiration volume | XN: 88 µL in whole blood (WB) mode and body fluid (BF) mode SP-50: 70 µL for smear preparation in auto mode, 38 µL for smear preparation in manual mode |
Throughput | XN: Quality control materialXN Check (three levels) and XN Check BF (two levels) |
Parameters | XN-CBC (always with NRBC) & XN-DIFF (always with IG) WBC, NRBC%, NRBC#, RBC, HGB, HCT, MCV, MCH, MCHC, PLT, RDW-SD, RDW-CV, MicroR%, MacroR%, PDW, MPV, P-LCR, PCT, NEUT%, NEUT#, LYMPH%, LYMPH#, MONO%, MONO#, EO%, EO#, BASO%, BASO#, IG%, IG# RET%, RET#, IRF, LFR, MFR, HFR, RET-He, RBC-He, Delta-He, HYPO-He%, HYPER-He%, PLT-O PLT-F, IPF, IPF# Extended Inflammation Parameters licence: NEUT-GI, NEUT-RI, RE-LYMP%, RE-LYMP#, AS-LYMP%, AS-LYMP# HPC%, HPC# WBC-BF, RBC-BF, MN%, MN#, PMN%, PMN#, TC-BF# |
Sysmex Middle East FZ-LLC
Dubai Healthcare City
City Pharmacy Building C/P 72, Office 304
P.O. Box 505119 Dubai, U.A.E.
+971 4 4370515
+971 4 4370516
This course is intended for daily or frequent operators of the XN-1500. Whether you're getting started or just want to refresh your knowledge, you will find useful information here.
Product documents
Safety data sheets
Regulatory Documents
Regulatory documents, such as Instructions for Use, can be accessed with a valid My Sysmex login:
Go to My Sysmex