XN-2000
a perfect pair for basic and extended testing
- 200 samples/h
- Sampler capacity 10 racks
- Choose diagnostic APPs as needed
- Integrated backup concept
- Short turnaround times
The XN-2000 system is a combination of two analysis modules that you can equip with a specified clinical application. In its Rerun & Reflex configuration, it is transformed into a superb solution for basic and extended testing. Because the two modules process rack samples simultaneously, it can accommodate any sample without slowing down. The modules work together perfectly. And you don’t lose any precious time, even with abnormal samples.
With integrated reflex testing, you no longer have to select and reload samples manually. The reflex sampler feeds the samples into the left-hand module automatically and performs the extended measurement. If there are no abnormal samples, it speeds up the system by working on standard samples instead.
Having two modules up and running means you have greater security for daily routines as you always have an integrated back-up solution at your disposal. To enhance the scope of your labs, you can network your XN-2000 with other XNs to create multiple-location installations. This lets you couple specialised and central laboratory units, and increase your service offering. And thanks to our remote services, we can together define levels of support quality, guaranteed service response times and ensure maximum system uptime.
Measurement principles | WBC DIFF/RET/PLT-F/WPC: Fluorescence Flow Cytometry RBC/PLT: Hydrodynamically focussed impedance HGB: Cyanide-free SLS haemoglobin |
Aspiration volume | 88 µL in whole blood (WB) mode and body fluid (BF) mode |
Throughput | up to 200 samples/h |
Quality control | XN Check (three levels) and XN Check BF (two levels) |
Parameters | XN-CBC (always with NRBC) & XN-DIFF (always with IG) Whole Blood WBC, NRBC%, NRBC#, RBC, HGB, HCT, MCV, MCH, MCHC, PLT, RDW-SD, RDW-CV, MicroR%, MacroR%, PDW, MPV, P-LCR, PCT, NEUT%, NEUT#, LYMPH%, LYMPH#, MONO%, MONO#, EO%, EO#, BASO%, BASO#, IG%, IG# With RET (optional) RET%, RET#, IRF, LFR, MFR, HFR, RET-He, RBC-He, Delta-He, HYPO-He%, HYPER-He%, PLT-O With PLT-F (optional) PLT-F, IPF, IPF# With WPC (optional) Extended Inflammation Parameters licence: NEUT-GI, NEUT-RI, RE-LYMP%, RE-LYMP#, AS-LYMP%, AS-LYMP# XN Stem Cells licence HPC%, HPC# Body Fluids with XN-BF WBC-BF, RBC-BF, MN%, MN#, PMN%, PMN#, TC-BF# (optional) |
Configurations | XN-2000 [DIFF] XN-2000 [WPC] |
Sysmex Middle East FZ-LLC
Dubai Healthcare City
City Pharmacy Building C/P 72, Office 304
P.O. Box 505119 Dubai, U.A.E.
+971 4 4370515
+971 4 4370516
Product documents
Safety data sheets
Regulatory Documents
Regulatory documents, such as Instructions for Use, can be accessed with a valid My Sysmex login:
Go to My Sysmex